dmdecode 常用命令
机器型号
[root@test_raid ~]# dmidecode | grep "Product"
Product Name: PowerEdge R720xd
Product Name: 068CDY
厂商
[root@test_raid ~]# dmidecode| grep "Manufacturer"
Manufacturer: Dell Inc.
序号信息
[root@test_raid ~]# dmidecode | grep -B 4 "Serial Number" | more
System Information
Manufacturer: Dell Inc.
Product Name: PowerEdge R720xd
Version: Not Specified
Serial Number: 8V3Q342
--
Base Board Information
Manufacturer: Dell Inc.
Product Name: 068CDY
Version: A01
Serial Number: ..CN779214AR02CC.
CPU 信息
[root@test_raid ~]# dmidecode | grep "CPU"
Socket Designation: CPU1
Version: Intel(R) Xeon(R) CPU E5-2695 v2 @ 2.40GHz
Socket Designation: CPU2
Version: Intel(R) Xeon(R) CPU E5-2695 v2 @ 2.40GHz
物理 CPU 个数
[root@test_raid ~]# dmidecode | grep "Socket Designation: CPU" |wc -l
2
生产日期
[root@test_raid ~]# dmidecode | grep "Date"
Release Date: 07/09/2014
megacli 常用命令
电源管理
充电状态
[root@test_raid ~]# megacli -AdpBbuCmd -GetBbuStatus -aALL |grep "Charger Status"
Charger Status: Complete
充电百分比
[root@test_raid ~]# megacli -AdpBbuCmd -GetBbuStatus -aALL |grep "Relative State of Charge"
Relative State of Charge: 100 %
当前 RAID 数量
[root@test_raid ~]# megacli -cfgdsply -aALL |grep "Number of DISK GROUPS:"
Number of DISK GROUPS: 1
信息检测
RAID 卡信息
[root@test_raid ~]# megacli -cfgdsply –aALL | more
==============================================================================
Adapter: 0
Product Name: PERC H710P Mini
Memory: 1024MB
BBU: Present
Serial No: 49F033N
==============================================================================
Number of DISK GROUPS: 1
DISK GROUP: 0
Number of Spans: 1
SPAN: 0
Span Reference: 0x00
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :system_vd
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 3.637 TB
Mirror Data : 3.637 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Ongoing Progresses:
Background Initialization: Completed 13%, Taken 63 min.
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 32
Slot Number: 0
Drive's postion: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 0
WWN: 5000C50062A960D0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 3.638 TB [0x1d1c0beb0 Sectors]
Non Coerced Size: 3.637 TB [0x1d1b0beb0 Sectors]
Coerced Size: 3.637 TB [0x1d1b00000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: GS0F
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50062a960d1
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6ABTC
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :29C (84.20 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Physical Disk: 1
Enclosure Device ID: 32
Slot Number: 1
Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: 1
Device Id: 1
WWN: 5000C50062A98C78
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 3.638 TB [0x1d1c0beb0 Sectors]
Non Coerced Size: 3.637 TB [0x1d1b0beb0 Sectors]
Coerced Size: 3.637 TB [0x1d1b00000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: GS0F
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50062a98c79
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6ABD4
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :29C (84.20 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
其他物理信息
[root@test_raid ~]# megacli -PDList -aALL
当前 RAID 磁盘信息
[root@test_raid ~]# megacli -LDInfo -LALL –aAll
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :system_vd
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 3.637 TB
Mirror Data : 3.637 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Ongoing Progresses:
Background Initialization: Completed 14%, Taken 64 min.
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
raid 控制器个数
[root@test_raid ~]# megacli -adpCount
Controller Count: 1.
raid 控制器时间
[root@test_raid ~]# megacli -AdpGetTime –aALL
Adapter 0:
Date: 12/31/2014
Time: 16:21:15
缓存及策略
raid cache 策略
[root@test_raid ~]# megacli -cfgdsply -aALL |grep Polic
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
查看磁盘缓存策略
[root@test_raid ~]# megacli -LDGetProp -Cache -L0 -a0 <- 第一个 RAID
[root@test_raid ~]# megacli -LDGetProp -Cache -L1 -a0 <- 第二个 RAID
[root@test_raid ~]# megacli -LDGetProp -Cache -LALL -a0
Adapter 0-VD 0(target id: 0): Cache Policy:WriteBack, ReadAdaptive, Direct, No Write Cache if bad BBU
设置磁盘缓存策略
缓存策略解释:
WT (Write through)
WB (Write back)
NORA (No read ahead)
RA (Read ahead)
ADRA (Adaptive read ahead)
Cached
Direct
-RW|RO|Blocked|RemoveBlocked | WT|WB|ForcedWB [-Immediate] |RA|NORA | DsblP | Cached|Direct | -EnDskCache|DisDskCache | CachedBadBBU|NoCachedBadBBU
-Lx|-L0,1,2|-Lall -aN|-a0,1,2|-aALL
设定直接回写
[root@test_raid ~]# megacli -LDSetProp WT -L0 -a0
Set Write Policy to WriteThrough on Adapter 0, VD 0 (target id: 0) success
直接回写
[root@test_raid ~]# megacli -LDSetProp -Direct -L0 -a0
Set Cache Policy to Direct on Adapter 0, VD 0 (target id: 0) success
关闭缓存
[root@test_raid ~]# megacli -LDSetProp -DisDskCache -L0 -a0
Set Disk Cache Policy to Disabled on Adapter 0, VD 0 (target id: 0) success
raid 管理
磁盘检测方法
查询磁盘个数, 序号
[root@test_raid ~]# megacli -PDList -aALL | grep 'Inquiry Data:'
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6ABTC
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6ABD4
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z69SFJ
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A4Z7
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A4X5
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A5YG
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6AB8R
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6AALM
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A4N0
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A51S
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z69ST5
Inquiry Data: SEAGATE ST4000NM0023 GS0FZ1Z6A4V1
[root@test_raid ~]# megacli -PDList -aALL | grep WWN
WWN: 5000C50062A960D0
WWN: 5000C50062A98C78
WWN: 5000C50062A9AF54
WWN: 5000C50062A98F30
WWN: 5000C50062A993AC
WWN: 5000C50062A93EA4
WWN: 5000C50062A9998C
WWN: 5000C50062A9CB4C
WWN: 5000C50062A9B52C
WWN: 5000C50062A98CB0
WWN: 5000C50062A99CF0
WWN: 5000C50062A99990
检测磁盘 ID 注意, 该ID 值用于标注磁盘
[root@test_raid ~]# megacli -PDlist -aALL | grep "ID" | uniq
Enclosure Device ID: 32
检测当前 raid 组及每个 raid 组对应的磁盘
[root@test_raid ~]# megacli -cfgdsply –aALL | grep -E "DISK\ GROUP|Slot\ Number"
Number of DISK GROUPS: 1
DISK GROUP: 0
Slot Number: 0
Slot Number: 1
查询当前磁盘的序号, 并且可以检测磁盘是否损坏 (注, 当前第 6 个磁盘出问题)
[root@test_raid ~]# megacli -PDList -aALL | grep -E "Drive\:\ \ Not\ Supported|Slo"
Slot Number: 0
Slot Number: 1
Slot Number: 2
Slot Number: 3
Slot Number: 4
Slot Number: 5
Drive: Not Supported
Slot Number: 6
Slot Number: 7
Slot Number: 8
Slot Number: 9
Slot Number: 10
Slot Number: 11
foreign 管理
创建 RAID 前, 需要检测是否具有 foreign 配置, 如果有需要清除( foreign = 某个新加入的磁盘之前已经创建了 RAID, 需要初始化)
[root@test_raid ~]# megacli -PDlist -aALL | grep "Foreign State"
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None (Foreign) 加入具有 foreign 配置, 则显示该配置 (对应上一个命令中 Slot Number: 5磁盘)
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None
Foreign State: None
把上面标注为 Foreign 磁盘标注为 unconfigrue good
[root@test_raid ~]# megacli -PDMakeGood -PhysDrv[32:5] -a0
Adapter: 0: Failed to change PD state at EnclId-32 SlotId-5. [由于当前并不是 foreign 状态, 因此返回错误]
Exit Code: 0x01
清除 foreign 配置
[root@test_raid ~]# megacli -CfgForeign -Scan -a0
There is no foreign configuration on controller 0.
Exit Code: 0x00
raid 0 管理
创建 raid 0 方法 ( 3 个磁盘 )
[root@test_raid ~]# megacli -CfgLdAdd -r0 [32:2,32:3,32:4] WB Direct -a0
Adapter 0: Created VD 1
Adapter 0: Configured the Adapter!!
Exit Code: 0x00
检查 raid 组与对应磁盘
[root@test_raid ~]# megacli -cfgdsply –aALL | grep -E "DISK\ GROUP|Slot\ Number|RAID\ Level|Target"
Number of DISK GROUPS: 2
DISK GROUP: 0
Virtual Drive: 0 (Target Id: 0) [磁盘虚拟 ID, 删除时候使用]
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 [primay-1] raid 1
Slot Number: 0
Slot Number: 1
DISK GROUP: 1
Virtual Drive: 1 (Target Id: 1)
RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 [primary-0] raid 0
Slot Number: 2
Slot Number: 3
Slot Number: 4
查询磁盘是否在创建中
[root@test_raid ~]# megacli -PDRbld -ProgDsply -PhysDrv [32:3,32,2,32,4] -aALL
Device(Encl-32 Slot-3) is not in rebuild process
Device(Encl-32 Slot-2) is not in rebuild process
Device(Encl-32 Slot-4) is not in rebuild process
删除某个 RAID
[root@test_raid ~]# megacli -CfgLdDel -L1 -a0
Virtual Disk is associate with Cache Cade. Please Use force option to delete <- 需要使用 force 参数
[root@test_raid ~]# megacli -CfgLdDel -L1 -force -a0
Adapter 0: Deleted Virtual Drive-1(target id-1)
Exit Code: 0x00
raid 1 管理
利用两个磁盘创建 RAID 1
[root@test_raid ~]# megacli -CfgLdAdd -r1 [32:5,32:6] WB Direct -a0
Adapter 0: Created VD 2
Adapter 0: Configured the Adapter!!
Exit Code: 0x00
检测方法
[root@test_raid ~]# megacli -cfgdsply –aALL | grep -E "DISK\ GROUP|Slot\ Number|RAID\ Level|Target"
Number of DISK GROUPS: 3
DISK GROUP: 0
Virtual Drive: 0 (Target Id: 0)
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Slot Number: 0
Slot Number: 1
DISK GROUP: 1
Virtual Drive: 1 (Target Id: 1)
RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0
Slot Number: 2
Slot Number: 3
Slot Number: 4
DISK GROUP: 2
Virtual Drive: 2 (Target Id: 2)
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Slot Number: 5
Slot Number: 6
删除方法同上
[root@test_raid ~]# megacli -CfgLdDel -L2 -force -a0
RAID 5 管理
一个热备 3 个组 RAID 方法
[root@test_raid ~]# megacli -CfgLdAdd -r5 [32:7,32:8,32:9] WB Direct -Hsp[32:10] -a0
Adapter 0: Created VD 3
Adapter: 0: Set Physical Drive at EnclId-32 SlotId-10 as Hot Spare Success.
Adapter 0: Configured the Adapter!!
Exit Code: 0x00
组 RAID 马上完成, 组 RAID 后, 马上能够在磁盘上看见设备名称
[root@test_raid ~]# megacli -PDRbld -ProgDsply -PhysDrv [32:7,32:8,32:9] -aALL
Device(Encl-32 Slot-7) is not in rebuild process
Device(Encl-32 Slot-8) is not in rebuild process
Device(Encl-32 Slot-9) is not in rebuild process
查询当前 RAID 5 磁盘大小
[root@test_raid ~]# fdisk -l /dev/sdd
Disk /dev/sdd: 8000.5 GB, 8000450330624 bytes
255 heads, 63 sectors/track, 972666 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x00000000
查询热盘方法
[root@test_raid ~]# megacli -PDList -aALL | grep -E "DISK\ GROUP|Slot\ Number|postion:|Firmware\ state:"
Slot Number: 0 <- 磁盘序号
Drive's postion: DiskGroup: 0, Span: 0, Arm: 0 <- DiskGroup: 0 标注当前属于那个 RAID 组
Firmware state: Online, Spun Up <- Online 标注磁盘当前在线
Slot Number: 1
Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 2
Drive's postion: DiskGroup: 1, Span: 0, Arm: 0
Firmware state: Online, Spun Up
Slot Number: 3
Drive's postion: DiskGroup: 1, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 4
Drive's postion: DiskGroup: 1, Span: 0, Arm: 2
Firmware state: Online, Spun Up
Slot Number: 5
Drive's postion: DiskGroup: 2, Span: 0, Arm: 0
Firmware state: Online, Spun Up
Slot Number: 6
Drive's postion: DiskGroup: 2, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 7
Drive's postion: DiskGroup: 3, Span: 0, Arm: 0
Firmware state: Online, Spun Up
Slot Number: 8
Drive's postion: DiskGroup: 3, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 9
Drive's postion: DiskGroup: 3, Span: 0, Arm: 2
Firmware state: Online, Spun Up
Slot Number: 10
Firmware state: Hotspare, Spun Up <- HotSpare 表示当前为热盘
Slot Number: 11
Firmware state: Unconfigured(good), Spun Up
RAID 5 扩容[失败]
[root@test_raid ~]# megacli -LDRecon -Start -r5 -Add -PhysDrv[32:11] -L3 -a0
Failed to Start Reconstruction of Virtual Drive.
FW error description:
The requested virtual drive operation cannot be performed because consistency check is in progress.
Exit Code: 0x17
故障模拟
模拟故障磁盘, 遇到故障后, 需要把磁盘执行 OFFLINE 操作
[root@test_raid ~]# megacli -PDOffline -PhysDrv [32:9] -a0
Adapter: 0: EnclId-32 SlotId-9 state changed to OffLine.
Exit Code: 0x00
当磁盘 9 执行 OFFLINE 后, 热备会自动 REBUILD
[root@test_raid ~]# megacli -PDList -aALL | grep -E "DISK\ GROUP|Slot\ Number|postion:|Firmware\ state:"
Drive's postion: DiskGroup: 3, Span: 0, Arm: 0
Firmware state: Online, Spun Up
Slot Number: 8
Drive's postion: DiskGroup: 3, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 9
Firmware state: Unconfigured(good), Spun Up <- offline 操作后状态会自动修改
Slot Number: 10
Drive's postion: DiskGroup: 3, Span: 0, Arm: 2
Firmware state: Rebuild <--- 自动进行 rebuild 状态
查询 rebuild 状态
[root@test_raid ~]# megacli -PDRbld -ProgDsply -PhysDrv [32:10] -aALL
Rebuild progress of physical drives...
Enclosure:Slot Percent Complete Time Elps
032 :10 ***********************00 %*********************** 00:03:44
把第九个磁盘重新作为热备使用
[root@test_raid ~]# megacli -PDHSP -Set -Dedicated -Array3 -physdrv[32:9] -a0
Adapter: 0: Set Physical Drive at EnclId-32 SlotId-9 as Hot Spare Success.
Exit Code: 0x00
查询状态
Firmware state: Online, Spun Up
Slot Number: 7
Drive's postion: DiskGroup: 3, Span: 0, Arm: 0
Firmware state: Online, Spun Up
Slot Number: 8
Drive's postion: DiskGroup: 3, Span: 0, Arm: 1
Firmware state: Online, Spun Up
Slot Number: 9
Firmware state: Hotspare, Spun Up
Slot Number: 10
Drive's postion: DiskGroup: 3, Span: 0, Arm: 2
Firmware state: Rebuild
让故障磁盘闪灯
[root@test_raid ~]# megacli -PdLocate -start -physdrv[32:11] -a0
Adapter: 0: Device at EnclId-32 SlotId-11 -- PD Locate Start Command was successfully sent to Firmware
Exit Code: 0x00
停止闪灯
[root@test_raid ~]# megacli -PdLocate -stop -physdrv[32:11] -a0
Adapter: 0: Device at EnclId-32 SlotId-11 -- PD Locate Stop Command was successfully sent to Firmware
Exit Code: 0x00
启动管理
指定启动的 raid 组
megacli -AdpBootDrive -set -L0 -a0
相关文章
- grep命令及正则表达式
- yum 指定安装某个源下的软件
- Dell服务器MegaCli命令只返回Exit Code: 0x00问题分析
- 使用MegaCli工具查看Raid磁盘阵列状态
- MegaCli 监控raid状态
- 常用PC服务器阵列卡、硬盘健康监控
转载请注明:爱开源 » dmdecode 与 megacli 命令用法参考
转载请注明:爱开源 » dmdecode 与 megacli 命令用法参考